Skip image slider

Silent Diesel Genset 200 kW for Standby and Prime Power Applications

This is a 200 kW diesel generating set built into a sound-attenuated enclosure — the kind of unit that sits beside a building or plant room and runs when the mains supply cannot

At 0.8 power factor that works out at roughly 250 kVA — enough to carry a mid-sized factory’s essential load, a hotel, a hospital wing, a data room, or a remote camp’s full demand. The enclosure does real work: sheet steel panels in sand-tone powder coating wrap the engine and alternator, with acoustic lining behind them and a black silencer housing mounted on top — that combination brings noise down to a level tolerable next to working areas and buildings (actual sound levels are measured and supplied in the test report with each set, since they depend on load, distance, and site conditions). Access is built for maintenance: large hinged doors with locks, one front door built with grille panels that let air through while keeping hands and tools out, and louvred vents at the ends handling intake and discharge air sized for the cooling airflow the package needs under continuous load. The control panel is a Deep Sea Electronics DSE7320 MKII — a mains-failure auto-start controller with LCD readout, navigation keys, and indicator lamps — beside a red emergency stop mushroom button, a battery charger switch, and a power switch. Everything sits on a heavy black base frame that carries the unit, provides mounting feet, and can be specified with integral fuel tankage.

Contact Form

Silent Diesel Genset 200 kW for Standby and Prime Power Applications Description

  1. A 200 kW package that covers a building’s essentials — lighting, lifts, pumps, HVAC in part, IT and communications, refrigeration, and production lines in a small to mid-sized plant; the size that puts a whole facility on backup power without stepping up to a containerised plant.
  2. Noise control built into the enclosure — acoustic lining inside the canopy and a dedicated silencer housing on top are part of the design, so the set can be sited near buildings, staff areas, or site boundaries; exact sound level documented in the test report for checking against local requirements.
  3. DSE7320 MKII control with automatic mains failure start — brings the set online when the mains drops and takes it off when supply returns, without anyone on site; also remote start, engine protection with automatic shutdown on fault, and a logged history readable from the display.
  4. Emergency stop and isolation within reach — red mushroom emergency stop beside the controller, with battery charger switch and power switch; shutdown controls grouped on one panel is a safety requirement as much as a convenience.
  5. Lockable service doors — large hinged doors that take locks; engineers get clear access to engine, filters, and terminals for service; between services the set stays closed against damage, dust, or interference.
  6. Graded vents, sized for continuous load — intake and discharge louvres at the enclosure ends move the cooling air the package needs, with the grille-panel door adding airflow without opening a way in; an enclosure that breathes properly keeps a 200 kW set at rated output instead of derating in hot weather.
  7. Heavy base frame for mounting and fuel — carries the set, gives a firm footing on a level pad, takes the mounting points for anti-vibration mounts, and can be specified with integral fuel tankage.

Silent Diesel Genset 200 kW for Standby and Prime Power Applications

  1. Factories and production plants — carries control systems, compressors, lighting, and lines that cannot be stopped mid-batch; auto-start brings it online without an operator; silenced enclosure can sit beside the plant.
  2. Hotels, resorts and commercial buildings — lifts, kitchen refrigeration, corridor and emergency lighting, water pumps, HVAC; runs essential circuits automatically on mains failure; enclosure keeps noise down where the building shares a boundary with guest areas or neighbours.
  3. Hospitals, clinics and laboratories — power that returns within seconds: theatres, cold storage for pharmaceuticals, diagnostic equipment, life support; auto-start and engine protection suit standby duty where failure to start is not an option.
  4. Data rooms and telecom installations — server rooms, switch sites, communications cabinets need continuous supply and clean shutdowns; logged event history gives a record of every start, stop, and fault.
  5. Construction and infrastructure sites — welfare facilities, lighting towers, dewatering pumps, tools; one 200 kW unit covers a substantial site or several sections of one, and moves with the project.
  6. Mining and remote camps — prime power beyond the grid running long periods under load; heavy base and integral fuel tankage keep running hours up between refuelling; enclosure protects against dust and weather.
  7. Agriculture and food processing — irrigation pumps, cooling systems, grain handling, cold stores; backup for equipment that cannot stop; can be specified for prime power on farms without a connection.

Silent Diesel Genset 200 kW for Standby and Prime Power Applications Detail Display

Related Products

Related News

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.
Jining China Power Machinery Co.,Ltd