Skip image slider

High Voltage Static Var Generator Support Grid Connection Stabilize Bus Voltage for Solar&Wind Power Plan

This 35kV high-voltage SVG series is specially designed for grid connection scenarios of large-scale new energy power stations, with a capacity range of 20Mvar to 50Mvar, and meets the grid connection technical specifications of new energy power stations in most countries and regions. It supports four-quadrant operation, can realize the continuous adjustment from rated inductive reactive power to rated capacitive reactive power, and can flexibly respond to the reactive power demand of the power grid when the photovoltaic and wind power output fluctuates. The equipment is equipped with optical fiber communication interface, which can be connected to the SCADA system of the power station to realize remote monitoring and automatic control, and meets the requirements of grid dispatching.

Contact Form

High Voltage Static Var Generator Support Grid Connection Stabilize Bus Voltage for Solar&Wind Power Plan Description

  1. Wide reactive power adjustment range: It can cover the full range of -1 to 1 times the rated capacity, which can meet the reactive power demand of the power station under different operating conditions such as full power generation, low power generation, and nighttime shutdown, and ensure that the power factor of the grid connection point is maintained above 0.99.
  2. Fast voltage support capability: When the grid voltage fluctuates, it can output the maximum reactive current within 3ms to support the bus voltage, avoid the off-grid of the power station due to voltage over-limit, and improve the grid connection compliance rate of the power station by 95%.
  3. Low voltage ride through (LVRT) and high voltage ride through (HVRT) functions: It meets the latest grid connection standards, can operate normally within the range of 0.2-1.3 times the rated voltage, and avoids the large-scale off-grid of new energy stations caused by grid faults.
  4. Intelligent adaptive control: It can automatically adjust the compensation strategy according to the output change of new energy and the grid state, without manual setting, and reduce the operation and maintenance workload of the power station.
  5. Anti-islanding protection function: When the grid is powered off, it can quickly detect the islanding state and exit the operation within 20ms, which ensures the safety of maintenance personnel and equipment.

High Voltage Static Var Generator Support Grid Connection Stabilize Bus Voltage for Solar&Wind Power Plan Applications

  • Large-scale ground photovoltaic power stations with installed capacity of 50MW and above
  • Onshore and offshore wind farms with installed capacity of 100MW and above
  • Energy storage power stations with battery energy storage systems
  • Hydroelectric power stations with peak shaving and frequency modulation requirements
  • Regional power grid substations with a large number of new energy connected

High Voltage Static Var Generator Support Grid Connection Stabilize Bus Voltage for Solar&Wind Power Plan Detail Display

Related Products

Related News

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.
Jining China Power Machinery Co.,Ltd